Printer-MIB DEFINITIONS ::= BEGIN IMPORTS -- MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, TimeTicks, NOTIFICATION-TYPE, -- OBJECT-IDENTITY, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF hrDeviceIndex, hrStorageIndex FROM HOST-RESOURCES-MIB; mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } printmib MODULE-IDENTITY LAST-UPDATED "9411250000Z" ORGANIZATION "IETF Printer MIB Working Group" CONTACT-INFO "Randy Turner Sharp Laboratories of America 5750 NW Pacific Rim Blvd Camas, WA 98607 rturner@sharplabs.com" DESCRIPTION "The MIB module for management of printers." ::= { mib-2 43 } -- -- Textual conventions for this MIB module -- -- -- Generic unspecific textual conventions -- PrtMediaUnitTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration. STATUS current DESCRIPTION "Units of measure for media dimensions." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4) } PrtCapacityUnitTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration. STATUS current DESCRIPTION "Units of measure for media capacity." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), sheets(8), feet(16), meters(17) } PrtPrintOrientationTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "A generic representation for printing orientation on a 'page'." SYNTAX INTEGER { other(1), portrait(3), landscape(4) } PrtCoverStatusTC ::= TEXTUAL-CONVENTION -- This is a type 2 enumeration. STATUS current DESCRIPTION "Values for encoding the state of a particular cover or access panel on the printer case or enclosure." SYNTAX INTEGER { other(1), coverOpen(3), coverClosed(4), interlockOpen(5), interlockClosed(6) } PrtSubUnitStatusTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration. STATUS current DESCRIPTION "Status of a printer sub-unit. The SubUnitStatus is an integer that is the sum of 5 distinct values, Availability, Non- Critical, Critical, On-line, and Transitioning. These values are: Availability Value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line State is On-Line 0 State is Off-Line 32 Transitioning Currently at intended state 0 Transitioning to intended state 64 " SYNTAX INTEGER (0..126) PresentOnOff ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration. STATUS current DESCRIPTION "Presence and configuration of a device or feature." SYNTAX INTEGER { other(1), on(3), off(4), notPresent(5) } CodedCharSet ::= TEXTUAL-CONVENTION -- This is a type 3 enumeration. STATUS current DESCRIPTION "A coded character set value that specifies both a set of characters that may be used and an encoding (as one or more octets) that is used to represent the characters in the set. These values are to be used to identify the encoding employed for strings in the MIB where this is not fixed by the MIB. Some objects that allow a choice of coded character set are: the prtLocalizationCharacterSet object in the LocalizationTable and prtInterpreterDefaultCharSetIn. The prtGeneralCurrentLocalization and prtConsoleLocalization objects in turn contain the index in the LocalizationTable of the current localization (country, language, and coded character set) of the 'description' objects and the console, respectively. The space of the coded character set enumeration has been divided into three regions. The first region (3-999) consists of coded character sets that have been standardized by some standard setting organization. This region is intended for standards that do not have subset implementations. The second region (1000-1999) is for the Unicode and ISO/IEC 10646 coded character sets together with a specification of a (set of) sub-repertoires that may occur. The third region (>1999) is intended for vendor specific coded character sets. NOTE: Unicode and ISO 10646 character coded data may be processed and stored in either Big Endian (most significant octet first) or Little Endian (least significant octet first) order. Intel x86, VAX, and Alpha/AXP architectures are examples of Little Endian processor architectures. Furthermore, in environments where either order may occur, so-called Unicode BYTE ORDER MARK (BOM) character (which is ISO 10646 ZERO WIDTH NO BREAK SPACE), coded as FEFF in two octets and 0000FEFF in four octets is used at the beginning of the data as a signature to indicate the order of the following data (See ISO 10646 Annex F). Thus either ordering and BOM may occur in print data streams sent to the interpreter. However, ISO 8824/8825 (ASN.1/BER) used by SNMP is quite clear that Big Endian order shall be used and BOM shall NOT be used in transmission in the protocol. Transmitting Unicode in Big Endian order in SNMP should not prove to be a hardship for Little Endian machines, since SNMP ASN.1/BER requires integers to be transmitted in Big Endian order as well. So SNMP implementations on Little Endian machines are already reversing the order of integers to make them Big Endian for transmission via SNMP. Also Unicode characters are usually treated as two-octet integers, not short text strings, so that it will be straightforward for Little Endian machines to reverse the order of Unicode character octets as well before transmitting them and after receiving them via the SNMP protocol. Where a given coded character set may be known by more than one name, the most commonly known name is used as the name of the enumeration and other names are shown in the comments. The comments also indicate where to find detailed information on the coded character set and briefly characterize its relationship to other similar coded character sets. The current list of character sets and their enumerated values used to reference them is contained in the IANA Character Set registry. The enum value is indicated by the MIB enum entry in the registry. The enum symbol is indicated by the Alias that starts with 'cs' for character set. The IANA character sets registry is available via anonymous ftp. The ftp server is ftp.isi.edu. The subdirectory is /in-notes/iana/assignments/. The file name is character-sets. To add a character set to the IANA Registry: 1. Format an entry like those in the current list, omitting the MIBenum value. 2. Send the entry with a request to add the entry to the character set list to iana@ISI.EDU. 3. The IANA will supply a unique MIBenum value and update the list." SYNTAX INTEGER { other(1) -- used if the designated coded -- character set is not currently in -- the enumeration -- See IANA Registry for standard character sets in the -- MIBenum range of 3-999. -- See IANA Registry for Unicode and vendor-supplied -- combinations of ISO collections and character sets based -- on Unicode in the MIBenum range of 1000-1999. -- See IANA Registry for vendor developed character sets -- in the MIBenum range of 2000-xxxx. } -- -- General Group textual-conventions -- PrtGeneralResetTC ::= TEXTUAL-CONVENTION -- This value is a type 3 enumeration STATUS current DESCRIPTION "Values for reading and writing the prtGeneralReset object. If a device does not have NVRAM, the device shall none the less respond to a SET with the value resetToNVRAM(5) with some sort of warm reset that resets the device to some implementation-defined state that is preferably under control of the system administrator by some means outside the scope of this MIB specification." SYNTAX INTEGER { notResetting(3), powerCycleReset(4), -- Cold Start resetToNVRAM(5), -- Warm Start resetToFactoryDefaults(6) -- Reset contents of -- NVRAM to factory -- defaults } -- -- Channel Group textual-conventions -- PrtChannelStateTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "The state of this print job delivery channel. The value determine whether control information and print data is allowed through this channel." SYNTAX INTEGER { other(1), printDataAccepted(3), noDataAccepted(4) } PrtChannelTypeTC ::= TEXTUAL-CONVENTION -- This is a type 2 enumeration. STATUS current DESCRIPTION "This enumeration indicates the type of channel that is receiving jobs." SYNTAX INTEGER { other(1), chSerialPort(3), chParallelPort(4), chIEEE1284Port(5), chSCSIPort(6), chAppleTalkPAP(7), -- AppleTalk Printer -- Access Protocol (PAP) -- -- prtChannelInformation entry: -- -- Printer Name -- Keyword: Name -- Syntax: Name -- Status: Optional -- Multiplicity: Single -- Description: The name of the -- printer within the AppleTalk -- naming scope chLPDServer(8), -- prtChannelInformation entry: -- -- Printer queue name -- Keyword: Queue -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: queue name as -- defined in RFC 1179. chNetwareRPrinter(9), -- Novell, Inc. -- For each entry of this type, the -- prtChannelInformation must have a pair -- of keywords. For Netware 3.x channels -- this must be a (PServer, Printer) pair. -- For Netware 4.x channels and for -- IntranetWare channels this must be a -- (NDSTree, NDSPrinter) pair. -- -- prtChannelInformation entries: -- Print Server Name -- Keyword: PServer -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The Pserver's SAP name -- -- Printer Number -- Keyword: Printer -- Syntax: Integer -- Status: Mandatory -- Multiplicity: Single -- Description: The printer number -- -- NDSTree -- Keyword: NDSTree -- Syntax: Name -- Multiplicity: Single -- Description: The tree's SAP name -- -- NDS Printer object -- Keyword: NDSPrinter -- Syntax: Text (Unicode) -- Status: Mandatory -- Multiplicity: Single -- Description: The fully qualified -- name of the Printer -- -- In the Netware 3.x environment, the -- client checks the Bindery object -- representing the named PServer. The -- client then checks for queues which -- are associated with the numbered -- printer. In the 4.x and IntraNetware -- environment, the client looks up the -- queues which are associated with the -- NDS Printer Object in the named Tree. -- Depending on client access rights to -- those queues, the client submits jobs -- to the appropriate queue. chNetwarePServer(10), -- Novell,Inc. -- For each entry of this type, the -- prtChannelInformation must have a pair -- of keywords. For Netware 3.x channels -- this must be a (Server, PServer) pair. -- For Netware 4.x and IntranetWare -- channels, this must be a -- (NDSTree, NDSPServer) pair. -- -- prtChannelInformation entries: -- -- Server Name -- Keyword: Server -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The SAP name of the -- server for which the PServer is -- defined. -- -- PServer -- Keyword: PServer -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The bindery name of -- the PServer -- -- NDS Tree -- Keyword: NDSTree -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The NDS Tree name -- -- PServer -- Keyword: NDSPServer -- Syntax: Text (Unicode) -- Status: Mandatory -- Multiplicity: Single -- Description: The fully qualified -- name of the PServer object in the -- tree. -- -- In the 3.x environment, the client -- checks the bindery object -- representing the named PServer on the -- named Server. In the 4.x and -- IntranetWare environment, -- the client checks the NDS object -- representing the named PServer in the -- named Tree. In either case, the -- client then checks for all queues -- associated with the Pserver object. -- Depending on client access rights -- to those queues, the client submits -- jobs to the appropriate queue. chPort9100(11), -- DEPRECATED chAppSocket(12), -- A bi-directional, LPD-like, -- protocol using 9101 for -- control and 9100 for data. -- Adobe Systems, Inc. chFTP(13), -- RFC 959 chTFTP(14), -- RFC 1350 chDLCLLCPort(15), chIBM3270(16), -- IBM Coax chIBM5250(17), -- IBM Twinax chFax(18), chIEEE1394(19), chTransport1(20), -- TCP port 35, see reserved TCP port list -- in RFC 1700 or current "Assigned -- Numbers" RFC. This RFC should also be -- referenced for other channel -- enumerations utilizing TCP port -- numbers 0 through 1024. chCPAP(21), -- TCP port 170, Digital -- Equipment Corp. chPCPrint(26), -- Banyan chServerMessageBlock(27), -- File/Print sharing protocol used by -- various network operating systems -- from IBM 3Com, Microsoft and others -- -- prtChannelInformation entry: -- -- Service Name -- Keyword: Name -- Syntax: Name -- Status: Optional -- Multiplicity: Single -- Description: The service name of -- the printer chPSM(28), -- Printing Systems -- Manager, IBM chSystemObjectManager(31), -- IBM chDECLAT(32), -- Digital Equipment Corp. -- -- prtChannelInformation entries: -- -- Port Name -- Keyword: Port -- Syntax: Name -- Status: Conditionally -- Mandatory -- (see note below) -- Multiplicity: Single -- Description: LAT port name -- -- Service Name -- Keyword: Service -- Syntax: Name -- Status: Conditionally -- Mandatory -- Multiplicity: Single -- Description: LAT service -- name -- -- The LAT channel may be -- identified by either a port or -- service, so either a -- Port or Service entry must be -- specified, but not both. chNPAP(33), chUSB(34), -- Universal Serial Bus chIRDA(35), -- Infrared Data Assoc. Prot. chPrintXChange(36), -- PrintXChange Protocol chPortTCP(37), -- A unidirectional "raw" TCP -- channel that uses an administratively -- assigned TCP port address. -- -- prtChannelInformation entry: -- -- Port Number -- Keyword: Port -- Syntax: decimal number -- Status: Mandatory -- Multiplicity: Single -- Description: TCP port number chBidirPortTCP(38), -- A bi-directional version of chPortTCP -- -- prtChannelInformation entries: -- (See chPortTCP) chUNPP(39), -- Universal Network Printing -- Protocol(UNPP). A bi-directional, -- multiport network printing -- application protocol available on -- multiple transport protocols. -- Underscore, Inc. -- Contact: info@underscore.com chAppleTalkADSP(40), -- AppleTalk Data Stream Protocol. -- ADSP is part of the AppleTalk -- suite of protocols. -- It is a symmetric, connection- -- oriented protocol that makes -- possible the establishment -- and maintenance of full-duplex -- streams of data bytes between -- two sockets in an AppleTalk -- internet. -- See Inside AppleTalk, second -- Edition, by Sidhu, Andrews and -- Oppenheimer. chPortSPX(41), -- Sequenced Packet Exchange (SPX) -- socket. -- Novell, Inc. Similar to TCP, a -- bi-directional data pipe using -- Novell SPX as a transport. -- -- prtChannelInformation entries: -- -- Network Number -- Keyword: Net -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The network number -- -- Node Number -- Keyword: Node -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The node number -- -- Socket Number -- Keyword: Socket -- Syntax: HexString -- Status: Mandatory -- Multiplicity: Single -- Description: The SPX socket number -- -- There must be exactly one "Net" and -- one "Node" and one "Socket" entry. A -- HexString is a binary value -- represented as a string of -- ASCII characters using hexadecimal -- notation. chPortHTTP(42), -- Hypertext Transfer Protocol. See IETF -- documents relating to HTTP 1.0/1.1 -- (RFCs 1945 and 2068,etc.) chNDPS(43) -- Novell, Inc. -- -- prtChannelInformation entry: -- -- Printer Agent Name -- Keyword: PA -- Syntax: Name -- Status: Mandatory -- Multiplicity: Single -- Description: The NDPS Printer -- Agent Name } -- Interpreter Group textual conventions PrtInterpreterLangFamilyTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration. STATUS current DESCRIPTION "This enumeration indicates the type of interpreter that is receiving jobs." SYNTAX INTEGER { other(1), unknown(2), langPCL(3), -- PCL. Starting with PCL version 5, -- HP-GL/2 is included as part of the -- PCL language. -- PCL and HP-GL/2 are registered -- trademarks of Hewlett-Packard -- Company. langHPGL(4), -- Hewlett-Packard Graphics Language. -- HP-GL is a registered trademark of -- Hewlett-Packard Company. langPJL(5), -- Peripheral Job Language. Appears in -- the data stream between data intended -- for a page description language. -- Hewlett-Packard Co. langPS(6), -- PostScript (tm) Language -- Postscript - a trademark of Adobe -- Systems Incorporated which may be -- registered in certain jurisdictions langIPDS(7), -- Intelligent Printer Data Stream -- Bi-directional print data stream for -- documents consisting of data objects -- (text, image, graphics, bar codes), -- resources (fonts, overlays) and page, -- form and finishing instructions. -- Facilitates system level device -- control, document tracking and error -- recovery throughout the print -- process. -- Pennant Systems, IBM langPPDS(8), -- IBM Personal Printer Data Stream. -- Originally called IBM ASCII, the name -- was changed to PPDS when the Laser -- Printer was introduced in 1989. -- Lexmark International, Inc. langEscapeP(9), -- Epson Corp. langEpson(10), langDDIF(11), -- Digital Document Interchange Format -- Digital Equipment Corp., Maynard MA langInterpress(12), -- Xerox Corp. langISO6429(13), -- ISO 6429. Control functions for -- Coded Character Sets (has ASCII -- control characters, plus additional -- controls for -- character imaging devices.) -- ISO Standard, Geneva, Switzerland langLineData(14),-- line-data: Lines of data as -- separate ASCII or EBCDIC records -- and containing no control functions -- (no CR, LF, HT, FF, etc.) -- For use with traditional line -- printers. May use CR and/or LF to -- delimit lines, instead of records. -- See ISO 10175 Document Printing -- Application(DPA) -- ISO standard, Geneva, Switzerland langMODCA(15), -- Mixed Object Document Content -- Architecture -- Definitions that allow the -- composition, interchange, and -- presentation of final form -- documents as a collection of data -- objects (text, image, graphics, bar -- codes), resources (fonts, overlays) -- and page, form and finishing -- instructions. -- Pennant Systems, IBM langREGIS(16), -- Remote Graphics Instruction Set, -- Digital Equipment Corp., Maynard MA langSCS(17), -- SNA Character String -- Bi-directional print data stream for -- SNA LU-1 mode of communication. -- IBM langSPDL(18), -- ISO 10180 Standard Page Description -- Language -- ISO Standard langTEK4014(19), -- Tektronix Corp. langPDS(20), langIGP(21), -- Printronix Corp. langCodeV(22), -- Magnum Code-V, Image and printer -- control language used to control -- impact/dot-matrix printers. -- QMS, Inc., Mobile AL langDSCDSE(23), -- DSC-DSE: Data Stream Compatible and -- Emulation Bi-directional print data -- stream for non-SNA (DSC) and SNA LU-3 -- 3270 controller (DSE) communications -- IBM langWPS(24), -- Windows Printing System, Resource -- based command/data stream used by -- Microsoft At Work Peripherals. -- Developed by the Microsoft -- Corporation. langLN03(25), -- Early DEC-PPL3, Digital Equipment -- Corp. langCCITT(26), langQUIC(27), -- QUIC (Quality Information Code), Page -- Description Language for laser -- printers. Included graphics, printer -- control capability and emulation of -- other well-known printer . -- QMS, Inc. langCPAP(28), -- Common Printer Access Protocol -- Digital Equipment Corp. langDecPPL(29), -- Digital ANSI-Compliant Printing -- Protocol -- (DEC-PPL) -- Digital Equipment Corp. langSimpleText(30), -- simple-text: character coded data, -- including NUL, CR , LF, HT, and FF -- control characters. See ISO 10175 -- Document Printing Application (DPA) -- ISO standard, Geneva, Switzerland langNPAP(31), -- Network Printer Alliance Protocol -- (NPAP). This protocol has been -- superseded by the IEEE 1284.1 TIPSI -- Std (ref. LangTIPSI(49)). langDOC(32), -- Document Option Commands, Appears in -- the data stream between data -- intended for a page description . -- QMS, Inc. langimPress(33), -- imPRESS, Page description language -- originally developed for the -- ImageServer product line. A binary -- language providing representations -- of text, simple graphics, and some -- large forms (simple -- bit-map and CCITT group ¾ -- encoded).The -- language was intended to be sent over -- an 8-bit channel and supported early -- document preparation languages (e.g. -- TeX and TROFF). -- QMS, Inc. langPinwriter(34), -- 24 wire dot matrix printer for -- USA, Europe, and Asia except -- Japan. -- More widely used in Germany, and -- some Asian countries than in US. -- NEC langNPDL(35), -- Page printer for Japanese market. -- NEC langNEC201PL(36),-- Serial printer language used in -- the Japanese market. -- NEC langAutomatic(37), -- Automatic PDL sensing. Automatic -- sensing of the interpreter -- language family by the printer -- examining the document content. -- Which actual interpreter language -- families are sensed depends on -- the printer implementation. langPages(38), -- Page printer Advanced Graphic -- Escape Set -- IBM Japan langLIPS(39), -- LBP Image Processing System langTIFF(40), -- Tagged Image File Format (Aldus) langDiagnostic(41), -- A hex dump of the input to the -- interpreter langPSPrinter(42), -- The PostScript Language used for -- control (with any PDLs) -- Adobe Systems Incorporated langCaPSL(43), -- Canon Print Systems Language langEXCL(44), -- Extended Command Language -- Talaris Systems Inc. langLCDS(45), -- Line Conditioned Data Stream -- Xerox Corporation langXES(46), -- Xerox Escape Sequences -- Xerox Corporation langPCLXL(47), -- Printer Control Language. Extended -- language features for printing, and -- printer control. -- Hewlett-Packard Co. langART(48), -- Advanced Rendering Tools (ART). -- Page Description language -- originally developed for the Laser -- Press printers. -- Technical reference manual: "ART IV -- Reference Manual", No F33M. -- Fuji Xerox Co., Ltd. langTIPSI(49), -- Transport Independent Printer -- System Interface (ref. IEEE Std. -- 1284.1) langPrescribe(50), -- Page description and printer -- control language. It can be -- described with ordinary ASCII -- Technical reference manual: -- "PRESCRIBE II Programming Manual" langLinePrinter(51), -- A simple-text character stream which -- supports the control codes LF, VT, -- FF, and plus Centronics or -- Dataproducts Vertical Format Unit -- (VFU) language is commonly used on -- many older model line and matrix -- printers. langIDP(52), -- Imaging Device Protocol -- Apple Computer. langXJCL(53), -- Xerox Job Control Language (JCL). -- A Job Control language originally -- developed for the LaserPress printers -- and is capable of switching PDLs. -- Technical reference manual: -- "ART IV Reference Manual", No F33M. -- Fuji Xerox Co., Ltd. langPDF(54), -- Adobe Portable Document Format -- Adobe Systems, Inc. langRPDL(55), -- Ricoh Page Description Language for -- printers. -- Technical manual "RPDL command -- reference" No.307029 -- RICOH, Co. LTD langIntermecIPL(56), -- Intermec Printer Language for label -- printers. -- Technical Manual: "IPL Programmers -- Reference Manual" -- Intermec Corporation langUBIFingerprint(57), -- An intelligent basic-like programming -- language for label printers. -- Reference Manual: "UBI Fingerprint -- 7.1", No. 1-960434-00 -- United Barcode Industries langUBIDirectProtocol(58) -- An intelligent control language for -- label printers. -- Programmers guide: " UBI Direct -- Protocol", No. 1-960419-00 -- United Barcode Industries } -- -- Input/Output Group Textual Conventions -- PrtInputTypeTC ::= TEXTUAL-CONVENTION -- This is a type 2 enumeration STATUS current DESCRIPTION "The type of technology (discriminated primarily according to feeder mechanism type) employed by a specific component or components." SYNTAX INTEGER { other(1), unknown(2), sheetFeedAutoRemovableTray(3), sheetFeedAutoNonRemovableTray(4), sheetFeedManual(5), continuousRoll(6), continuousFanFold(7) } PrtOutputTypeTC ::= TEXTUAL-CONVENTION -- This is a type 2 enumeration STATUS current DESCRIPTION "The Type of technology supported by this output sub-unit" SYNTAX INTEGER { other(1), unknown(2), removableBin(3), unRemovableBin(4), continuousRollDevice(5), mailBox(6), continuousFanFold(7) } PrtOutputStackingOrderTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration STATUS current DESCRIPTION "The current state of the stacking order for the associated output sub-unit. 'firstToLast' means that as pages are output, the front of the next page is placed against the back of the previous page. 'lastToFirst' means that as pages are output, the back of the next page is placed against the front of the previous page." SYNTAX INTEGER { unknown(2), firstToLast(3), lastToFirst(4) } PrtOutputPageDeliveryOrientationTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration STATUS current DESCRIPTION "The reading surface that will be 'up' when pages are delivered to the associated output sub- unit. Values are Face-Up and Face-Down (Note: interpretation of these values is, in general, context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user." SYNTAX INTEGER { faceUp(3), faceDown(4) } -- -- Marker Group Textual Conventions -- PrtMarkerMarkTechTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration STATUS current DESCRIPTION "The type of marking technology used for this marking sub-unit" SYNTAX INTEGER { other(1), unknown(2), electrophotographicLED(3), electrophotographicLaser(4), electrophotographicOther(5), impactMovingHeadDotMatrix9pin(6), impactMovingHeadDotMatrix24pin(7), impactMovingHeadDotMatrixOther(8), impactMovingHeadFullyFormed(9), impactBand(10), impactOther(11), inkjetAqueous(12), inkjetSolid(13), inkjetOther(14), pen(15), thermalTransfer(16), thermalSensitive(17), thermalDiffusion(18), thermalOther(19), electroerosion(20), electrostatic(21), photographicMicrofiche(22), photographicImagesetter(23), photographicOther(24), ionDeposition(25), eBeam(26), typesetter(27) } PrtMarkerCounterUnitTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), characters(5), lines(6), impressions(7), sheets(8), dotRow(9), hours(11), feet(16), meters(17) } PrtMarkerSuppliesTypeTC ::= TEXTUAL-CONVENTION -- This value is a type 3 enumeration STATUS current DESCRIPTION "The type of this supply." SYNTAX INTEGER { other(1), unknown(2), toner(3), wasteToner(4), ink(5), inkCartridge(6), inkRibbon(7), wasteInk(8), opc(9), -- photo conductor developer(10), fuserOil(11), solidWax(12), ribbonWax(13), wasteWax(14), fuser(15), coronaWire(16), fuserOilWick(17), cleanerUnit(18), fuserCleaningPad(19), transferUnit(20), tonerCartridge(21), fuserOiler(22) } PrtMarkerSuppliesSupplyUnitTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "Unit of this marker supply container/receptacle." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), impressions(7), sheets(8), thousandthsOfOunces(12), hours(11), tenthsOfGrams(13), hundrethsOfFluidOunces(14), tenthsOfMilliliters(15), feet(16), meters(17) } PrtMarkerSuppliesClassTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled." SYNTAX INTEGER { other(1), supplyThatIsConsumed(3), receptacleThatIsFilled(4) } PrtMarkerColorantRoleTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "The role played by this colorant." SYNTAX INTEGER { -- Colorant Role other(1), process(3), spot(4) } -- -- Media Path Textual Conventions -- PrtMediaPathMaxSpeedPrintUnitTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "The unit of measure used in specifying the speed of all media paths in the printer." SYNTAX INTEGER { tenThousandthsOfInchesPerHour(3),-- .0001/hour micrometersPerHour(4), charactersPerHour(5), linesPerHour(6), impressionsPerHour(7), sheetsPerHour(8), dotRowPerHour(9), feetPerHour(16), metersPerHour(17) } PrtMediaPathTypeTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration STATUS current DESCRIPTION "The type of the media path for this media path." SYNTAX INTEGER { other(1), unknown(2), longEdgeBindingDuplex(3), shortEdgeBindingDuplex(4), simplex(5) } -- -- Interpreter Group Textual Conventions -- PrtInterpreterTwoWayTC ::= TEXTUAL-CONVENTION -- This is a type 1 enumeration STATUS current DESCRIPTION "Indicates whether or not this interpreter returns information back to the host." SYNTAX INTEGER { yes(3), no(4) } -- -- Console Group Textual Conventions -- PrtConsoleColorTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration STATUS current DESCRIPTION "The color of this light." SYNTAX INTEGER { other(1), unknown(2), white(3), red(4), green(5), blue(6), cyan(7), magenta(8), yellow(9), orange(10) } -- -- Alert Group Textual Conventions -- PrtAlertSeverityLevelTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration STATUS current DESCRIPTION "The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. A warning is defined to be a non-critical alert. The value also indicates whether the event is a binary change event or a unary change event." SYNTAX INTEGER { other(1), criticalBinaryChangeEvent(3), warningUnaryChangeEvent(4), warningBinaryChangeEvent(5) } PrtAlertTrainingLevelTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration STATUS current DESCRIPTION "The level of training required to handle this alert, if human intervention is required. The noInterventionRequired value should be used if the event does not require any human intervention. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or the training required to handle this alert. The printer will break alerts into these different training levels. It is the responsibility of the management application in the system to determine how a particular alert is handled and how and to whom that alert is routed. The following are the four training levels of alerts: Field Service - Alerts that typically require advanced training and technical knowledge of the printer and its sub-units. An example of a technical person would be a manufacturer's Field Service representative, or other person formally trained by the manufacturer or similar representative. Trained - Alerts that require an intermediate or moderate level of knowledge of the printer and its sub-units. A typical examples of alerts that a trained operator can handle is replacing toner cartridges. Untrained - Alerts that can be fixed without prior training either because the action to correct the alert is obvious or the printer can help the untrained person fix the problem. A typical example of such an alert is reloading paper trays and emptying output bins on a low end printer. Management - Alerts that have to do with overall operation of and configuration of the printer. Examples of management events are configuration change of sub-units." SYNTAX INTEGER { other(1), unknown(2), untrained(3), trained(4), fieldService(5), management(6), noInterventionRequired(7) } PrtAlertGroupTC ::= TEXTUAL-CONVENTION -- This value is a type 1 enumeration for values in the range -- 1 to 29. -- Values of 30 and greater are type 2 enumerations and are -- for use in other MIBs that augment tables in the Printer -- MIB. Therefore, other MIBs may assign alert codes of 30 or -- higher to use the alert table from the Printer MIB without -- requiring revising and re-publishing this document. STATUS current DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printer MIB. NOTE: Alert type codes have been added for the host resources MIB storage table and device table. These additional types are for situations in which the printer's storage and device objects must generate alerts (and possibly traps for critical alerts)." SYNTAX INTEGER { other(1), hostResourcesMIBStorageTable(3), hostResourcesMIBDeviceTable(4), generalPrinter(5), cover(6), localization(7), input(8), output(9), marker(10), markerSupplies(11), markerColorant(12), mediaPath(13), channel(14), interpreter(15), consoleDisplayBuffer(16), consoleLights(17), alert(18) } PrtAlertCodeTC ::= TEXTUAL-CONVENTION -- This value is a type 2 enumeration STATUS current DESCRIPTION "The code that describes the type of alert for this entry in the table. Binary change event alerts describe states of the subunit while unary change event alerts describe a single event. The same alert code can be used for a binary change event or a unary change event, depending on implementation. Also, the same alert code can be used to indicate a critical or a non-critical (warning) alert, depending on implementation. The value of prtAlertSeverityLevel specifies binary vs. unary and critical vs. non-critical for each event for the implementation. While there are some specific codes for many subunits, the generic codes should be used for most subunit alerts. The network management station can then query the subunit specified by prtAlertGroup to determine further subunit status and other subunit information. An agent shall not add two entries to the alert table for the same event, one containing a generic event code and the other containing a specific event code; the agent shall add only one entry in the alert table for each event; either generic (preferred) or specific, not both. Implementation of the unary change event alertRemovalOfBinaryChangeEntry(1801) is optional. When implemented, this alert code shall indicate to network management stations that the trailing edge of a binary change event has occurred and the corresponding alert entry has been removed from the alert table. As with all events, the alertRemovalOfBinaryChangeEntry(1801) alert shall be placed at the end of the alert table. Such an alert table entry shall specify the following information: prtAlertSeverityLevel warningUnaryChangeEvent(4) prtAlertTrainingLevel noInterventionRequired(7) prtAlertGroup alert(18) prtAlertGroupIndex the index of the row in the alert table of the binary change event that this event has removed. prtAlertLocation unknown (-2) prtAlertCode alertRemovalOfBinaryChangeEntry(1801) prtAlertDescription prtAlertTime the value of sysUpTime at the time of the removal of the binary change event from the alert table. Optionally, the agent may generate a trap coincident with removing the binary change event and placing the unary change event alertRemovalOfBinaryChangeEntry(1801) in the alert table. For such a trap, the prtAlertIndex sent with the above trap parameters shall be the index of the alertRemovalOfBinaryChangeEvent row that was added to the prtAlertTable; not the index of the row that was removed from the prtAlertTable." SYNTAX INTEGER { other(1), -- an event that is not represented -- by one of the alert codes -- specified below. unknown(2), -- The following generic codes are common -- to multiple groups. The NMS may -- examine the prtAlertGroup object -- to determine what group to query for -- further information. coverOpened(3), coverClosed(4), interlockOpened(5), interlockClosed(6), configurationChanged(7), jammed(8), subunitMissing(9), -- The subunit tray, bin, etc. -- has been removed. subunitLifeAlmostOver(10), subunitLifeOver(11), subunitAlmostEmpty(12), subunitEmpty(13), subunitAlmostFull(14), subunitFull(15), subunitNearLimit(16), subunitAtLimit(17), subunitOpened(18), subunitClosed(19), subunitTurnedOn(20), subunitTurnedOff(21), subunitOffline(22), subunitPowerSaver(23), subunitWarmingUp(24), subunitAdded(25), subunitRemoved(26), subunitResourceAdded(27), subunitResourceRemoved(28), subunitRecoverableFailure(29), subunitUnrecoverableFailure(30), subunitRecoverableStorageError(31), subunitUnrecoverableStorageError(32), subunitMotorFailure(33), subunitMemoryExhausted(34), subunitUnderTemperature(35), subunitOverTemperature(36), subunitTimingFailure(37), subunitThermistorFailure(38), -- general Printer group doorOpen(501), -- DEPRECATED -- Use coverOpened(3) doorClosed(502), -- DEPRECATED -- Use coverClosed(4) poweredUp(503), poweredDown(504), printerNMSReset(505), -- The printer has been reset by some -- network management station(NMS) -- writing into 'prtGeneralReset'. printerManualReset(506), -- The printer has been reset manually. printerReadyToPrint(507), -- The printer is ready to print. (i.e., -- not warming up, not in power save -- state, not adjusting print quality, -- etc.). -- Input Group inputMediaTrayMissing(801), inputMediaSizeChanged(802), inputMediaWeightChanged(803), inputMediaTypeChanged(804), inputMediaColorChanged(805), inputMediaFormPartsChange(806), inputMediaSupplyLow(807), inputMediaSupplyEmpty(808), inputMediaChangeRequest(809), -- An interpreter has detected that a -- different medium is need in this input -- tray subunit. The prtAlertDescription may -- be used to convey a human readable -- description of the medium required to -- satisfy the request. inputManualInputRequest(810), -- An interpreter has detected that manual -- input is required in this subunit. The -- prtAlertDescription may be used to convey -- a human readable description of the medium -- required to satisfy the request. inputTrayPositionFailure(811), -- The input tray failed to position -- correctly. inputTrayElevationFailure(812), inputCannotFeedSizeSelected(813), -- Output Group outputMediaTrayMissing(901), outputMediaTrayAlmostFull(902), outputMediaTrayFull(903), outputMailboxSelectFailure(904), -- Marker group markerFuserUnderTemperature(1001), markerFuserOverTemperature(1002), markerFuserTimingFailure(1003), markerFuserThermistorFailure(1004), markerAdjustingPrintQuality(1005), -- Marker Supplies group markerTonerEmpty(1101), markerInkEmpty(1102), markerPrintRibbonEmpty(1103), markerTonerAlmostEmpty(1104), markerInkAlmostEmpty(1105), markerPrintRibbonAlmostEmpty(1106), markerWasteTonerReceptacleAlmostFull(1107), markerWasteInkReceptacleAlmostFull(1108), markerWasteTonerReceptacleFull(1109), markerWasteInkReceptacleFull(1110), markerOpcLifeAlmostOver(1111), markerOpcLifeOver(1112), markerDeveloperAlmostEmpty(1113), markerDeveloperEmpty(1114), markerTonerCartridgeMissing(1115), -- Media Path Device Group mediaPathMediaTrayMissing(1301), mediaPathMediaTrayAlmostFull(1302), mediaPathMediaTrayFull(1303), -- Interpreter Group interpreterMemoryIncreased(1501), interpreterMemoryDecreased(1502), interpreterCartridgeAdded(1503), interpreterCartridgeDeleted(1504), interpreterResourceAdded(1505), interpreterResourceDeleted(1506), interpreterResourceUnavailable(1507), interpreterComplexPageEncountered(1509), -- The interpreter has encountered a page -- that is too complex for the resources that -- are available. -- Alert Group alertRemovalOfBinaryChangeEntry(1801) -- A binary change event entry has been -- removed from the alert table. This unary -- change alert table entry is added to the -- end of the alert table. } -- The General Printer Group -- -- The general printer sub-unit is responsible for the overall -- control and status of the printer. There is exactly one -- general printer sub-unit in a printer. -- -- Implementation of every object in this group is mandatory. prtGeneral OBJECT IDENTIFIER ::= { printmib 5 } prtGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of general information per printer. Objects in this table are defined in various places in the MIB, nearby the groups to which they apply. They are all defined here to minimize the number of tables that would otherwise need to exist." ::= { prtGeneral 1 } prtGeneralEntry OBJECT-TYPE SYNTAX PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry exists in this table for each device entry in the host resources MIB device table with a device type of 'printer'" INDEX { hrDeviceIndex } ::= { prtGeneralTable 1 } PrtGeneralEntry ::= SEQUENCE { -- Note that not all of the objects in this sequence are in -- the general printer group. The group to which a -- object belongs is tagged with a label "General", "Input" -- "Output", etc. after each entry in the following sequence -- prtGeneralConfigChanges Counter32, -- General prtGeneralCurrentLocalization Integer32, -- General prtGeneralReset PrtGeneralResetTC, -- General prtGeneralCurrentOperator OCTET STRING, -- Responsible Party prtGeneralServicePerson OCTET STRING, -- Responsible Party prtInputDefaultIndex Integer32, -- Input prtOutputDefaultIndex Integer32, -- Output prtMarkerDefaultIndex Integer32, -- Marker prtMediaPathDefaultIndex Integer32, -- Media Path prtConsoleLocalization Integer32, -- Console prtConsoleNumberOfDisplayLines Integer32, -- Console prtConsoleNumberOfDisplayChars Integer32, -- Console prtConsoleDisable INTEGER, -- Console, prtAuxiliarySheetStartupPage PresentOnOff, -- AuxiliarySheet prtAuxiliarySheetBannerPage PresentOnOff, -- AuxiliarySheet, prtGeneralPrinterName OCTET STRING, -- General prtGeneralSerialNumber OCTET STRING, -- General prtAlertCriticalEvents Counter32, -- Alert prtAlertAllEvents Counter32 -- Alert } prtGeneralConfigChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts configuration changes within the printer. A configuration change is defined to be an action that results in a change to any MIB object other than those that reflect status or level, or those that act as counters or gauges. In addition, any action that results in a row being added or deleted from any table in the Printer MIB is considered a configuration change. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub-units within the printer. This object should be incremented whenever the agent wishes to notify management applications that any cached configuration information for this device is to be considered 'stale'. At this point, the management application should flush any configuration information cached about this device and fetch new configuration information. The following are examples of actions that would cause the prtGeneralConfigChanges object to be incremented: - Adding an output bin - Changing the media in a sensing input tray - Changing the value of prtInputMediaType Note that the prtGeneralConfigChanges counter would not be incremented when an input tray is removed, or the level of an input device changes." ::= { prtGeneralEntry 1 } prtGeneralCurrentLocalization OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or to any object that is not explicitly identified as being localized according to prtGeneralCurrentLocalization." ::= { prtGeneralEntry 2 } prtGeneralReset OBJECT-TYPE -- This value is a type 3 enumeration SYNTAX PrtGeneralResetTC MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value 'notResetting(3)', and a SET of the value 'notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values 'notResetting' and 'resetToNVRAM'." ::= { prtGeneralEntry 3 } -- The Responsible Party group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtGeneralCurrentOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the person who is responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number. As a convention to facilitate automatic notification of the operator by the agent or the network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, spaces and parentheses, which shall be ignored. Phone numbers may also include ASCII comma characters(hex 2C) that are used to indicate a two- second pause during the dialing sequence. If either the phone, fax, or email information is not available, then a line should not be included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements." ::= { prtGeneralEntry 4 } prtGeneralServicePerson OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the person responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number. As a convention to facilitate automatic notification of the service person by the agent or a network management station, the phone number, fax number or email address should be placed on a separate line starting with ASCII LF (hex 0x0A) and the ASCII text string (without the quotes): 'phone: ', 'fax: ', and 'email: ', respectively. Phone numbers may contain digits, spaces and parentheses, which shall be ignored. Phone numbers can also include one or more ASCII comma characters(hex 2C) to indicate a two-second pause during the dialing sequence. If either the phone, fax, or email information is not available, then a line should not included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to RFC 822 requirements." ::= { prtGeneralEntry 5 } -- Default indexes section -- -- The following four objects are used to specify the indexes of -- certain subunits used as defaults during the printing process. prtInputDefaultIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media. This value shall be -1 if there is no default input subunit specified for the printer as a whole. In this case, the actual default input subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters." ::= { prtGeneralEntry 6 } prtOutputDefaultIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination. This value shall be -1 if there is no default output subunit specified for the printer as a whole. In this case, the actual default output subunit may be specified by means outside the scope of this MIB, such as by each interpreter in a printer with multiple interpreters." ::= { prtGeneralEntry 7 } prtMarkerDefaultIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the default marker sub-unit; that is, this object selects the default marker." ::= { prtGeneralEntry 8 } prtMediaPathDefaultIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path." ::= { prtGeneralEntry 9 } -- Console general section -- -- The following four objects describe overall parameters of the -- printer console subsystem. prtConsoleLocalization OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management operations." ::= { prtGeneralEntry 10 } prtConsoleNumberOfDisplayLines OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display" ::= { prtGeneralEntry 11 } prtConsoleNumberOfDisplayChars OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display" ::= { prtGeneralEntry 12 } prtConsoleDisable OBJECT-TYPE SYNTAX INTEGER { operatorConsoleEnabled(3), operatorConsoleDisabled(4), operatorConsoleEnabledLevel1(5), operatorConsoleEnabledLevel2(6), operatorConsoleEnabledLevel3(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "If the object prtConsoleDisable has value 'operatorConsoleDisabled' then input is not accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabled' then input is accepted from the operator console. If the object prtConsoleDisable has the value 'operatorConsoleEnabledLevel1', 'operatorConsoleEnabledLevel2' or 'operatorConsoleEnabledLevel3' then limited input is accepted from the operator console; the limitations are product specific, however, the limitations are generally less restrictive for operatorConsoleEnabledLevel1 than for operatorConsoleEnabledLeve2, which is less restrictive than operatorConsoleEnabledLevel3. The value of the prtConsoleDisable object is a type-2 enumeration." ::= { prtGeneralEntry 13 } -- The Auxiliary Sheet Group -- -- The auxiliary sheet group allows the administrator to control -- the production of auxiliary sheets by the printer. This group -- contains only the "prtAuxiliarySheetStartupPage" and -- "prtAuxiliarySheetBannerPage" objects. -- -- This group is optional. However, to claim conformance to this -- group it is necessary to implement every object in the group. prtAuxiliarySheetStartupPage OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable or disable printing a startup page. If enabled, a startup page will be printed shortly after power-up, when the device is ready. Typical startup pages include test patterns and/or printer configuration information." ::= { prtGeneralEntry 14 } prtAuxiliarySheetBannerPage OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable or disable printing banner pages at the beginning of jobs. This is a master switch which applies to all jobs, regardless of interpreter." ::= { prtGeneralEntry 15 } -- Administrative section -- -- The following two objects are used to specify administrative -- information assigned to the printer. prtGeneralPrinterName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "An administrator-specified name for this printer. Depending upon implementation of this printer, the value of this object may or may not be same as the value for the MIB-II 'SysName' object." ::= { prtGeneralEntry 16 } prtGeneralSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "A recorded serial number for this device that indexes some type device catalog or inventory. This value is usually set by the device manufacturer but the MIB supports the option of writing for this object for site-specific administration of device inventory or tracking." ::= { prtGeneralEntry 17 } -- General alert table section -- -- The following two objects are used to specify counters -- associated with the Alert Table. prtAlertCriticalEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A running counter of the number of critical alert events that have been recorded in the alert table. The value of this object is RESET in the event of a power cycle operation (i.e., the value is not persistent." ::= { prtGeneralEntry 18 } prtAlertAllEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table" ::= { prtGeneralEntry 19 } -- The Cover Table -- -- The cover portion of the General print sub-unit describes the -- covers and interlocks of the printer. The Cover Table has an -- entry for each cover and interlock. prtCover OBJECT IDENTIFIER ::= { printmib 6 } prtCoverTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCoverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the covers and interlocks of the printer." ::= { prtCover 1 } prtCoverEntry OBJECT-TYPE SYNTAX PrtCoverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a cover or interlock. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtCoverIndex } ::= { prtCoverTable 1 } PrtCoverEntry ::= SEQUENCE { prtCoverIndex Integer32, prtCoverDescription OCTET STRING, prtCoverStatus PrtCoverStatusTC } prtCoverIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this Cover sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new cover sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtCoverEntry 1 } prtCoverDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization." ::= { prtCoverEntry 2 } prtCoverStatus OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtCoverStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this cover sub-unit." ::= { prtCoverEntry 3 } -- The Localization Table -- -- The localization portion of the General printer sub-unit is -- responsible for identifying the natural language, country, and -- character set in which character strings are expressed. There -- may be one or more localizations supported per printer. The -- available localizations are represented by the Localization -- table. prtLocalization OBJECT IDENTIFIER ::= { printmib 7 } prtLocalizationTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtLocalizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The available localizations in this printer." ::= { prtLocalization 1 } prtLocalizationEntry OBJECT-TYPE SYNTAX PrtLocalizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A description of a localization. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtLocalizationIndex } ::= { prtLocalizationTable 1 } PrtLocalizationEntry ::= SEQUENCE { prtLocalizationIndex Integer32, prtLocalizationLanguage DisplayString, prtLocalizationCountry DisplayString, prtLocalizationCharacterSet CodedCharSet } prtLocalizationIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this localization entry. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new localization data to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtLocalizationEntry 1 } prtLocalizationLanguage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "A two character language code from ISO 639. Examples en, gb, ca, fr, de." ::= { prtLocalizationEntry 2 } prtLocalizationCountry OBJECT-TYPE SYNTAX DisplayString (SIZE(0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ..." ::= { prtLocalizationEntry 3 } prtLocalizationCharacterSet OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-only STATUS current DESCRIPTION "The coded character set used for this localization." ::= { prtLocalizationEntry 4 } -- The System Resources Tables -- -- The Printer MIB makes use of the Host Resources MIB to -- define system resources by referencing the storage -- and device groups of the print group. In order to -- determine, amongst multiple printers serviced by -- one agent, which printer owns a particular resource, -- the prtStorageRef and prtDeviceRef tables associate -- particular storage and device entries to printers. prtStorageRefTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtStorageRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtGeneral 2 } prtStorageRefEntry OBJECT-TYPE SYNTAX PrtStorageRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will have an entry for each entry in the Host Resources MIB storage table that represents storage associated with a printer managed by this agent." INDEX { hrStorageIndex, prtStorageRefSeqNumber } ::= { prtStorageRefTable 1 } PrtStorageRefEntry ::= SEQUENCE { prtStorageRefSeqNumber Integer32, prtStorageRefIndex Integer32 } prtStorageRefSeqNumber OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value will be unique amongst all entries with a common value of hrStorageIndex. This object allows a storage entry to point to the multiple printer devices with which it is associated." ::= { prtStorageRefEntry 1 } prtStorageRefIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the hrDeviceIndex of the printer device that this storageEntry is associated with." ::= { prtStorageRefEntry 2 } prtDeviceRefTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDeviceRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtGeneral 3 } prtDeviceRefEntry OBJECT-TYPE SYNTAX PrtDeviceRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will have an entry for each entry in the Host Resources MIB device table that represents a device associated with a printer managed by this agent." INDEX { hrDeviceIndex, prtDeviceRefSeqNumber } ::= { prtDeviceRefTable 1 } PrtDeviceRefEntry ::= SEQUENCE { prtDeviceRefSeqNumber Integer32, prtDeviceRefIndex Integer32 } prtDeviceRefSeqNumber OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value will be unique amongst all entries with a common value of hrDeviceIndex. This object allows a device entry to point to the multiple printer devices with which it is associated." ::= { prtDeviceRefEntry 1 } prtDeviceRefIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with." ::= { prtDeviceRefEntry 2 } -- The Input Group -- -- Input sub-units are managed as a tabular, indexed collection -- of possible devices capable of providing media for input to -- the printing process. Input sub-units typically have a -- location, a type, an identifier, a set of constraints on -- possible media sizes and potentially other media -- characteristics, and may be capable of indicating current -- status or capacity. -- -- Implementation of every object in this group is mandatory. prtInput OBJECT IDENTIFIER ::= { printmib 8 } prtInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the devices capable of providing media for input to the printing process." ::= { prtInput 2 } prtInputEntry OBJECT-TYPE SYNTAX PrtInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a device capable of providing media for input to the printing process. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtInputIndex } ::= { prtInputTable 1 } PrtInputEntry ::= SEQUENCE { prtInputIndex Integer32, prtInputType PrtInputTypeTC, prtInputDimUnit PrtMediaUnitTC, prtInputMediaDimFeedDirDeclared Integer32, prtInputMediaDimXFeedDirDeclared Integer32, prtInputMediaDimFeedDirChosen Integer32, prtInputMediaDimXFeedDirChosen Integer32, prtInputCapacityUnit PrtCapacityUnitTC, prtInputMaxCapacity Integer32, prtInputCurrentLevel Integer32, prtInputStatus PrtSubUnitStatusTC, prtInputMediaName OCTET STRING, prtInputName OCTET STRING, prtInputVendorName OCTET STRING, prtInputModel OCTET STRING, prtInputVersion OCTET STRING, prtInputSerialNumber OCTET STRING, prtInputDescription OCTET STRING, prtInputSecurity PresentOnOff, prtInputMediaWeight Integer32, prtInputMediaType OCTET STRING, prtInputMediaColor OCTET STRING, prtInputMediaFormParts Integer32, prtInputMediaLoadTimeout Integer32, prtInputNextIndex Integer32 } prtInputIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this input sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of n input sub- units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtInputEntry 1 } prtInputType OBJECT-TYPE SYNTAX PrtInputTypeTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice." ::= { prtInputEntry 2 } prtInputDimUnit OBJECT-TYPE SYNTAX PrtMediaUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use calculating and relaying dimensional values for this input sub-unit." ::= { prtInputEntry 3 } prtInputMediaDimFeedDirDeclared OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 4 } prtInputMediaDimXFeedDirDeclared OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 5 } prtInputMediaDimFeedDirChosen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken relative to the feed direction associated with that sub- unit and are in input sub-unit dimensional units (MediaUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 6 } prtInputMediaDimXFeedDirChosen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (MediaUnit). If the printer supports the declare dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (- 2) indicates unknown." ::= { prtInputEntry 7 } prtInputCapacityUnit OBJECT-TYPE SYNTAX PrtCapacityUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this input sub-unit." ::= { prtInputEntry 8 } prtInputMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtInputEntry 9 } prtInputCurrentLevel OBJECT-TYPE SYNTAX Integer32 -- in capacity units -- (PrtCapacityUnitTC). MAX-ACCESS read-write STATUS current DESCRIPTION "The current capacity of the input sub-unit in input sub-unit capacity units (PrtCapacityUnitTC). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that at least one unit remains." ::= { prtInputEntry 10 } prtInputStatus OBJECT-TYPE SYNTAX PrtSubUnitStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this input sub-unit." ::= { prtInputEntry 11 } prtInputMediaName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media attributes (e.g. prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputMediaWeight, prtInputMediaType). An example would be 'legal tender bond paper'." REFERENCE "See Appendix C, 'Media Names'." ::= { prtInputEntry 12 } -- INPUT MEASUREMENT -- -- _______ | | -- ^ | | -- | | | | -- | |_ _ _ _ _ _ _ _| _______________ |direction -- | | | ^ v -- MaxCapacity | Sheets | | -- | | left | CurrentLevel -- | | in | | -- v | tray | v -- _______ +_______________+ _______ -- The Extended Input Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtInputName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to this input sub-unit." ::= { prtInputEntry 13 } prtInputVendorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor name of this input sub-unit." ::= { prtInputEntry 14 } prtInputModel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name of this input sub-unit." ::= { prtInputEntry 15 } prtInputVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of this input sub-unit." ::= { prtInputEntry 16 } prtInputSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number assigned to this input sub-unit." ::= { prtInputEntry 17 } prtInputDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization." ::= { prtInputEntry 18 } prtInputSecurity OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this input sub-unit has some security associated with it." ::= { prtInputEntry 19 } -- The Input Media Group -- -- The Input Media Group supports identification of media -- installed or available for use on a printing device. -- Medium resources are identified by name, and include a -- collection of characteristic attributes that may further be -- used for selection and management of them. -- The Input Media group consists of a set of optional -- "columns" in the Input Table. In this manner, a minimally -- conforming implementation may choose to not support reporting -- of media resources if it cannot do so. -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtInputMediaWeight OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The weight of the medium associated with this input sub-unit in grams / per meter squared. The value (-2) means unknown." ::= { prtInputEntry 20 } prtInputMediaType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the type of medium associated with this input sub-unit. This name need not be processed by the printer; it might simply be displayed to an operator. The standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are: stationery Separately cut sheets of an opaque material transparency Separately cut sheets of a transparent material envelope Envelopes that can be used for conventional mailing purposes envelope-plain Envelopes that are not preprinted and have no windows envelope-window Envelopes that have windows for addressing purposes continuous-long Continuously connected sheets of an opaque material connected along the long edge continuous-short Continuously connected sheets of an opaque material connected along the short edge tab-stock Media with tabs multi-part-form Form medium composed of multiple layers not pre-attached to one another; each sheet may be drawn separately from an input source labels Label stock multi-layer Form medium composed of multiple layers which are pre-attached to one another; e.g., for use with impact printers. Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes." ::= { prtInputEntry 21 } prtInputMediaColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the color of the medium associated with this input sub-unit using standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white pink yellow buff goldenrod blue green transparent Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes." ::= { prtInputEntry 22 } prtInputMediaFormParts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of parts associated with the medium associated with this input sub-unit if the medium is a multi-part form. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means unknown." ::= { prtInputEntry 23 } -- The Input Switching Group -- -- The input switching group allows the administrator to set the -- input subunit time-out for the printer and to control the -- automatic input subunit switching by the printer when an input -- subunit becomes empty. -- -- This group is optional. However, to claim conformance to this -- group, it is required to implement every object in the group. prtInputMediaLoadTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "When the printer is not able to print due to a subunit being empty or the requested media must be manually loaded, the printer will wait for the duration (in seconds) specified by this object. Upon expiration of the time-out, the printer will take the action specified by prtInputNextIndex. The event which causes the printer to enter the waiting state is product specific. If the printer is not waiting for manually fed media, it may switch from an empty subunit to a different subunit without waiting for the time-out to expire. A value of (-1) implies 'other' or 'infinite' which translates to 'wait forever'. The action which causes printing to continue is product specific. A value of (-2) implies 'unknown'." ::= { prtInputEntry 24 } prtInputNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInputIndex corresponding to the input subunit which will be used when this input subunit is emptied and the time-out specified by prtInputMediaLoadTimeout expires. A value of zero(0) indicates that auto input switching will not occur when this input subunit is emptied. If the time-out specified by prtInputLoadMediaTimeout expires and this value is zero(0), the job will be aborted. A value of (-1) means other. The value (-2) means 'unknown' and specifically indicates that an implementation specific method will determine the next input subunit to use at the time this subunit is emptied and the time-out expires. The value(-3) means input switching is not supported for this subunit." ::= { prtInputEntry 25 } -- The Output Group -- -- Output sub-units are managed as a tabular, indexed collection -- of possible devices capable of receiving media delivered from -- the printing process. Output sub-units typically have a -- location, a type, an identifier, a set of constraints on -- possible media sizes and potentially other characteristics, -- and may be capable of indicating current status or capacity. -- -- Implementation of every object in this group is mandatory. prtOutput OBJECT IDENTIFIER ::= { printmib 9 } prtOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the devices capable of receiving media delivered from the printing process." ::= { prtOutput 2 } prtOutputEntry OBJECT-TYPE SYNTAX PrtOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a device capable of receiving media delivered from the printing process. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtOutputIndex } ::= { prtOutputTable 1 } PrtOutputEntry ::= SEQUENCE { prtOutputIndex Integer32, prtOutputType PrtOutputTypeTC, prtOutputCapacityUnit PrtCapacityUnitTC, prtOutputMaxCapacity Integer32, prtOutputRemainingCapacity Integer32, prtOutputStatus PrtSubUnitStatusTC, prtOutputName OCTET STRING, prtOutputVendorName OCTET STRING, prtOutputModel OCTET STRING, prtOutputVersion OCTET STRING, prtOutputSerialNumber OCTET STRING, prtOutputDescription OCTET STRING, prtOutputSecurity PresentOnOff, prtOutputDimUnit PrtMediaUnitTC, prtOutputMaxDimFeedDir Integer32, prtOutputMaxDimXFeedDir Integer32, prtOutputMinDimFeedDir Integer32, prtOutputMinDimXFeedDir Integer32, prtOutputStackingOrder PrtOutputStackingOrderTC, prtOutputPageDeliveryOrientation PrtOutputPageDeliveryOrientationTC, prtOutputBursting PresentOnOff, prtOutputDecollating PresentOnOff, prtOutputPageCollated PresentOnOff, prtOutputOffsetStacking PresentOnOff } prtOutputIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by this printer to identify this output sub-unit. Although these values may change due to a major reconfiguration of the sub-unit (e.g. the addition of new output devices to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtOutputEntry 1 } prtOutputType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtOutputTypeTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of technology supported by this output sub-unit." ::= { prtOutputEntry 2 } prtOutputCapacityUnit OBJECT-TYPE SYNTAX PrtCapacityUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this output sub-unit." ::= { prtOutputEntry 3 } prtOutputMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of this output sub-unit in output sub-unit capacity units (PrtCapacityUnitTC). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtOutputEntry 4 } prtOutputRemainingCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (PrtCapacityUnitTC)of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that there remains capacity for at least one unit." ::= { prtOutputEntry 5 } prtOutputStatus OBJECT-TYPE SYNTAX PrtSubUnitStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this output sub-unit." ::= { prtOutputEntry 6 } -- OUTPUT MEASUREMENT -- -- _______ | | ________ -- ^ | | ^ -- | | | | -- | | |RemainingCapacity -- MaxCapacity| | | -- | | | v ^ -- | |_ _ _ _ _ _ _ _ | _______________ |direction -- | | Sheets | | -- | | in | -- v | Output | -- _______ +________________+ -- The Extended Output Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to this output sub-unit." ::= { prtOutputEntry 7 } prtOutputVendorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor name of this output sub-unit." ::= { prtOutputEntry 8 } prtOutputModel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name assigned to this output sub-unit." ::= { prtOutputEntry 9 } prtOutputVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of this output sub-unit." ::= { prtOutputEntry 10 } prtOutputSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number assigned to this output sub-unit." ::= { prtOutputEntry 11 } prtOutputDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization." ::= { prtOutputEntry 12 } prtOutputSecurity OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this output sub-unit has some security associated with it and if that security is enabled or not." ::= { prtOutputEntry 13 } -- The Output Dimensions Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputDimUnit OBJECT-TYPE SYNTAX PrtMediaUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying dimensional values for this output sub-unit." ::= { prtOutputEntry 14 } prtOutputMaxDimFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (MediaUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 15 } prtOutputMaxDimXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (MediaUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 16 } prtOutputMinDimFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 17 } prtOutputMinDimXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 18 } -- The Output Features Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputStackingOrder OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtOutputStackingOrderTC MAX-ACCESS read-write STATUS current DESCRIPTION "The current state of the stacking order for the associated output sub-unit. 'FirstToLast' means that as pages are output the front of the next page is placed against the back of the previous page. 'LasttoFirst' means that as pages are output the back of the next page is placed against the front of the previous page." ::= { prtOutputEntry 19 } prtOutputPageDeliveryOrientation OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtOutputPageDeliveryOrientationTC MAX-ACCESS read-write STATUS current DESCRIPTION "The reading surface that will be 'up' when pages are delivered to the associated output sub-unit. Values are faceUp and faceDown. (Note: interpretation of these values is in general context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user)." ::= { prtOutputEntry 20 } prtOutputBursting OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the outputting sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous media is separated into individual sheets, typically by bursting along pre-formed perforations." ::= { prtOutputEntry 21 } prtOutputDecollating OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individual parts within a multi-part form are separated and sorted into separate stacks for each part." ::= { prtOutputEntry 22 } prtOutputPageCollated OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled. See glossary for definition of how this document defines collation." ::= { prtOutputEntry 23 } prtOutputOffsetStacking OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output supports offset stacking, and if so, whether the feature is enabled. See glossary for how Offset Stacking is defined by this document." ::= { prtOutputEntry 24 } -- The Marker Group -- -- A marker is the mechanism that produces marks on the print -- media. The marker sub-units and their associated supplies are -- represented by the Marker Group in the model. A printer can -- contain one or more marking mechanisms. Some examples of -- multiple marker sub-units are: a printer -- with separate markers for normal and magnetic ink or an -- imagesetter that can output to both a proofing device and -- final film. Each marking device can have its own set of -- characteristics associated with it, such as marking technology -- and resolution. -- -- Implementation of every object in this group is mandatory. prtMarker OBJECT IDENTIFIER ::= { printmib 10 } -- The printable area margins as listed below define an area of -- the print media which is guaranteed to be printable for all -- combinations of input, media paths, and interpreters for this -- marker. prtMarkerTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtMarker 2 } prtMarkerEntry OBJECT-TYPE SYNTAX PrtMarkerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtMarkerIndex } ::= { prtMarkerTable 1 } PrtMarkerEntry ::= SEQUENCE { prtMarkerIndex Integer32, prtMarkerMarkTech PrtMarkerMarkTechTC, prtMarkerCounterUnit PrtMarkerCounterUnitTC, prtMarkerLifeCount Counter32, prtMarkerPowerOnCount Counter32, prtMarkerProcessColorants Integer32, prtMarkerSpotColorants Integer32, prtMarkerAddressabilityUnit INTEGER, prtMarkerAddressabilityFeedDir Integer32, prtMarkerAddressabilityXFeedDir Integer32, prtMarkerNorthMargin Integer32, prtMarkerSouthMargin Integer32, prtMarkerWestMargin Integer32, prtMarkerEastMargin Integer32, prtMarkerStatus PrtSubUnitStatusTC } prtMarkerIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marking SubUnit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marking sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMarkerEntry 1 } prtMarkerMarkTech OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtMarkerMarkTechTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 } prtMarkerCounterUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtMarkerCounterUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets." ::= { prtMarkerEntry 3 } prtMarkerLifeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of the number of units of measure counted during the life of printer using units of measure as specified by prtMarkerCounterUnit." ::= { prtMarkerEntry 4 } prtMarkerPowerOnCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by prtMarkerCounterUnit." ::= { prtMarkerEntry 5 } prtMarkerProcessColorants OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and prtMarkerSpotColorants cannot both be 0. The value of prtMarkerProcessColorants must be 0 or greater." ::= { prtMarkerEntry 6 } prtMarkerSpotColorants OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of spot colors supported by this marker. The value of this object and prtMarkerProcessColorants cannot both be 0. Must be 0 or greater." ::= { prtMarkerEntry 7 } prtMarkerAddressabilityUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measure of distances, as applied to the marker's resolution." ::= { prtMarkerEntry 8 } prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of addressable marking positions in the feed direction per 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 9 } prtMarkerAddressabilityXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of addressable marking positions in the cross feed direction in 10000 units of measure specified by prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 10 } prtMarkerNorthMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin, in units identified by prtMarkerAddressabilityUnit, from the leading edge of the medium as the medium flows through the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (- 2) means unknown." ::= { prtMarkerEntry 11 } prtMarkerSouthMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the South edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 12 } prtMarkerWestMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the West edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 13 } prtMarkerEastMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the East edge (see prtMarkerNorthMargin) of the medium in units identified by prtMarkerAddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 14 } prtMarkerStatus OBJECT-TYPE SYNTAX PrtSubUnitStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this marker sub-unit." ::= { prtMarkerEntry 15 } -- The Marker Supplies Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 } prtMarkerSuppliesTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the marker supplies available on this printer." ::= { prtMarkerSupplies 1 } prtMarkerSuppliesEntry OBJECT-TYPE SYNTAX PrtMarkerSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a marker supply. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtMarkerSuppliesIndex } ::= { prtMarkerSuppliesTable 1 } PrtMarkerSuppliesEntry ::= SEQUENCE { prtMarkerSuppliesIndex Integer32, prtMarkerSuppliesMarkerIndex Integer32, prtMarkerSuppliesColorantIndex Integer32, prtMarkerSuppliesClass PrtMarkerSuppliesClassTC, prtMarkerSuppliesType PrtMarkerSuppliesTypeTC, prtMarkerSuppliesDescription OCTET STRING, prtMarkerSuppliesSupplyUnit PrtMarkerSuppliesSupplyUnitTC, prtMarkerSuppliesMaxCapacity Integer32, prtMarkerSuppliesLevel Integer32 } prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across successive power cycles." ::= { prtMarkerSuppliesEntry 1 } prtMarkerSuppliesMarkerIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated." ::= { prtMarkerSuppliesEntry 2 } prtMarkerSuppliesColorantIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table or if this supply does not depend on a single specified colorant." ::= { prtMarkerSuppliesEntry 3 } prtMarkerSuppliesClass OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtMarkerSuppliesClassTC MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled." ::= { prtMarkerSuppliesEntry 4 } prtMarkerSuppliesType OBJECT-TYPE -- This value is a type 3 enumeration SYNTAX PrtMarkerSuppliesTypeTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this supply." ::= { prtMarkerSuppliesEntry 5 } prtMarkerSuppliesDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization." ::= { prtMarkerSuppliesEntry 6 } prtMarkerSuppliesSupplyUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtMarkerSuppliesSupplyUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of measure of this marker supply container/receptacle." ::= { prtMarkerSuppliesEntry 7 } prtMarkerSuppliesMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtMarkerSuppliesEntry 8 } prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The current level if this supply is a container; remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is reported by the printer and is read-only; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 } -- The Marker Colorant Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 } prtMarkerColorantTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerColorantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of all of the colorants available on the printer." ::= { prtMarkerColorant 1 } prtMarkerColorantEntry OBJECT-TYPE SYNTAX PrtMarkerColorantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a colorant available on the printer. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtMarkerColorantIndex } ::= { prtMarkerColorantTable 1 } PrtMarkerColorantEntry ::= SEQUENCE { prtMarkerColorantIndex Integer32, prtMarkerColorantMarkerIndex Integer32, prtMarkerColorantRole PrtMarkerColorantRoleTC, prtMarkerColorantValue OCTET STRING, prtMarkerColorantTonality Integer32 } prtMarkerColorantIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this colorant. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new colorants to the printer)." ::= { prtMarkerColorantEntry 1 } prtMarkerColorantMarkerIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the marker sub-unit with which this colorant entry is associated." ::= { prtMarkerColorantEntry 2 } prtMarkerColorantRole OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtMarkerColorantRoleTC MAX-ACCESS read-only STATUS current DESCRIPTION "The role played by this colorant." ::= { prtMarkerColorantEntry 3 } prtMarkerColorantValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white red green blue cyan magenta yellow black Implementers may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes" ::= { prtMarkerColorantEntry 4 } prtMarkerColorantTonality OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distinct levels of tonality realizable by a marking sub-unit when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least 2." ::= { prtMarkerColorantEntry 5 } -- The Media Path Group -- -- The media paths encompass the mechanisms in the printer that -- move the media through the printer and connect all other media -- related sub-units: inputs, outputs, markers and finishers. A -- printer contains one or more media paths. These are -- represented by the Media Path Group in the model. The Media -- Path group has some attributes that apply to all -- paths plus a table of the separate media paths. prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 } prtMediaPathTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMediaPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtMediaPath 4 } prtMediaPathEntry OBJECT-TYPE SYNTAX PrtMediaPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtMediaPathIndex } ::= { prtMediaPathTable 1 } PrtMediaPathEntry ::= SEQUENCE { prtMediaPathIndex Integer32, prtMediaPathMaxSpeedPrintUnit PrtMediaPathMaxSpeedPrintUnitTC, prtMediaPathMediaSizeUnit PrtMediaUnitTC, prtMediaPathMaxSpeed Integer32, prtMediaPathMaxMediaFeedDir Integer32, prtMediaPathMaxMediaXFeedDir Integer32, prtMediaPathMinMediaFeedDir Integer32, prtMediaPathMinMediaXFeedDir Integer32, prtMediaPathType PrtMediaPathTypeTC, prtMediaPathDescription OCTET STRING, prtMediaPathStatus PrtSubUnitStatusTC } prtMediaPathIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this media path. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new media paths to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMediaPathEntry 1 } prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtMediaPathMaxSpeedPrintUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measure used in specifying the speed of all media paths in the printer." ::= { prtMediaPathEntry 2 } prtMediaPathMediaSizeUnit OBJECT-TYPE SYNTAX PrtMediaUnitTC MAX-ACCESS read-only STATUS current DESCRIPTION "The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer." ::= { prtMediaPathEntry 3 } prtMediaPathMaxSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'." ::= { prtMediaPathEntry 4 } prtMediaPathMaxMediaFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum physical media size in the feed direction of this media path expressed in units of measure specified by PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited' a value of (-2) implies 'unknown'" ::= { prtMediaPathEntry 5 } prtMediaPathMaxMediaXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 6 } prtMediaPathMinMediaFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum physical media size in the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 7 } prtMediaPathMinMediaXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum physical media size across the feed direction of this media path expressed in units of measure specified by prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 8 } prtMediaPathType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtMediaPathTypeTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the media path for this media path." ::= { prtMediaPathEntry 9 } prtMediaPathDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization." ::= { prtMediaPathEntry 10 } prtMediaPathStatus OBJECT-TYPE SYNTAX PrtSubUnitStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this media path." ::= { prtMediaPathEntry 11 } -- The Print Job Delivery Channel Group -- -- Implementation of every object in this group is mandatory. -- -- Print Job Delivery Channels are independent sources of print -- data. Here, print data is the term used for the information -- that is used to construct printed pages and may have both data -- and control aspects. The output of a channel is in a form -- suitable for input to one of the interpreters as a -- stream. A channel may be independently enabled (allowing -- print data to flow) or disabled (stopping the flow of -- print data). A printer may have one or more channels. -- -- The Print Job Delivery Channel table describes the -- capabilities of the printer and not what is currently being -- performed by the printer -- -- Basically, the print job delivery channel abstraction -- describes the final processing step of getting the print data -- to an interpreter. It might include some level of -- decompression or decoding of print stream data. -- channel. All of these aspects are hidden in the channel -- abstraction. -- -- There are many kinds of print job delivery channels; some of -- which are based on networks and others which are not. For -- example, a channel can be a serial (or parallel) connection; -- it can be a service, such as the UNIX Line Printer Daemon -- (LPD), offering services over a network connection; or -- it could be a disk drive into which a floppy disk with -- the print data is inserted. Each print job delivery channel is -- identified by the electronic path and/or service protocol -- used to deliver print data to a print data interpreter. -- -- Channel example Implementation -- -- serial port channel bi-directional data channel -- parallel port channel often uni-directional channel -- IEEE 1284 port channel bi-directional channel -- SCSI port channel bi-directional -- Apple PAP channel may be based on LocalTalk, -- Ethernet or Tokentalk -- LPD Server channel TCP/IP based, port 515 -- Netware Remote Printer SPX/IPX based channel -- Netware Print Server SPX/IPX based channel -- -- It is easy to note that this is a mixed bag. There are -- some physical connections over which no (or very meager) -- protocols are run (e.g. the serial or old parallel ports) -- and there are services which often have elaborate -- protocols that run over a number of protocol stacks. In -- the end, what is important is the delivery of print data -- through the channel. -- -- The print job delivery channel sub-units are represented by -- the Print Job Delivery Channel Group in the Model. It has a -- current print job control language, which can be used to -- specify which interpreter is to be used for the print data and -- to query and change environment variables used by the -- interpreters (and Management Applications). There is also a -- default interpreter that is to be used if an interpreter is -- not explicitly specified using the Control Language. -- The first seven items in the Print Job Delivery Channel Table -- define the "channel" itself. A channel typically depends on -- other protocols and interfaces to provide the data that flows -- through the channel. -- -- Control of a print job delivery channel is largely limited to -- enabling or disabling the entire channel itself. It is likely -- that more control of the process of accessing print data -- will be needed over time. Thus, the ChannelType will -- allow type-specific data to be associated with each -- channel (using ChannelType specific groups in a fashion -- analogous to the media specific MIBs that are associated -- with the IANAIfType in the Interfaces Table). As a first -- step in this direction, each channel will identify the -- underlying Interface on which it is based. This is the -- eighth object in each row of the table. -- The Print Job Delivery Channel Table -- -- The prtChannelTable represents the set of input data sources -- which can provide print data to one or more of the -- interpreters available on a printer prtChannel OBJECT IDENTIFIER ::= { printmib 14 } prtChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtChannel 1 } prtChannelEntry OBJECT-TYPE SYNTAX PrtChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtChannelIndex } ::= { prtChannelTable 1 } PrtChannelEntry ::= SEQUENCE { prtChannelIndex Integer32, prtChannelType PrtChannelTypeTC, prtChannelProtocolVersion OCTET STRING, prtChannelCurrentJobCntlLangIndex Integer32, prtChannelDefaultPageDescLangIndex Integer32, prtChannelState PrtChannelStateTC, prtChannelIfIndex Integer32, prtChannelStatus PrtSubUnitStatusTC, prtChannelInformation OCTET STRING } prtChannelIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this data channel. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new data channels to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtChannelEntry 1 } prtChannelType OBJECT-TYPE SYNTAX PrtChannelTypeTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this print data channel. This object provides the linkage to ChannelType- specific groups that may (conceptually) extend the prtChannelTable with additional details about that channel." ::= { prtChannelEntry 2 } prtChannelProtocolVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType." ::= { prtChannelEntry 3 } prtChannelCurrentJobCntlLangIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control functions, such as querying or changing environment variables and identifying job boundaries (e.g. PJL, PostScript, NPAP). A value of zero indicates that there is no current Job Control Language Interpreter for this channel" ::= { prtChannelEntry 4 } prtChannelDefaultPageDescLangIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Description Language interpreter to be used for the print data unless the Control Language is used to select a specific interpreter (e.g., PCL, PostScript Language, auto-sense). A value of zero indicates that there is no default page description language interpreter for this channel." ::= { prtChannelEntry 5 } prtChannelState OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtChannelStateTC MAX-ACCESS read-write STATUS current DESCRIPTION "The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not." ::= { prtChannelEntry 6 } prtChannelIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is relevant, this is the index of the row representing the topmost layer in the interface hierarchy. A value of zero indicates that no interface is associated with this channel." ::= { prtChannelEntry 7 } prtChannelStatus OBJECT-TYPE SYNTAX PrtSubUnitStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the channel." ::= { prtChannelEntry 8 } prtChannelInformation OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Auxiliary information to allow a printing application to use the channel for data submission to the printer. An application capable of using a specific PrtChannelType should be able to use the combined information from the prtChannelInformation and other channel and interface group objects to 'bootstrap' its use of the channel. prtChannelInformation is not intended to provide a general channel description, nor to provide information that is available once the channel is in use. The encoding and interpretation of the prtChannelInformation object is specific to channel type. The description of each PrtChannelType enum value for which prtChannelInformation is defined specifies the appropriate encoding and interpretation, including interaction with other objects. For channel types that do not specify a prtChannelInformation value, its value shall be null (0 length). When a new PrtChannelType enumeration value is registered, its accompanying description must specify the encoding and interpretation of the prtChannelInformation value for the channel type. prtChannelInformation semantics for an existing PrtChannelType may be added or amended in the same manner as described in section 2.4.1 for type 2 enumeration values. The prtChannelInformation specifies values for a collection of channel attributes, represented as text according to the following rules: 1. The prtChannelInformation is not affected by localization. 2. The prtChannelInformation is a list of entries representing the attribute values. Each entry consists of the following items, in order: a. a keyword, composed of alphabetic characters (A-Z, a-z) represented by their NVT ASCII [NVT ASCII] codes, that identifies a channel attribute, b. the NVT ASCII code for an Equals Sign (=) (code 61) to delimit the keyword, c. a data value encoded using rules specific to the PrtChannelType to with the prtChannelInformation applies which must in no case allow an octet with value 10 (the NVT ASCII Line Feed code), d. the NVT ASCII code for a Line Feed character (code 10) to delimit the data value. No other octets shall be present. Keywords are case-sensitive. Conventionally, keywords are capitalized (including each word of a multi-word keyword) and since they occupy space in the prtChannelInformation, they are kept short. 3. If a channel attribute has multiple values, it is represented by multiple entries with the same keyword, each specifying one value. Otherwise, there shall be at most one entry for each attribute. 4. By default, entries may appear in any order. If there are ordering constraints for particular entries, these must be specified in their definitions. 5. The prtChannelInformation value by default consists of text represented by NVT ASCII graphics character codes. However, other representations may be specified: a. In cases where the prtChannelInformation value contains information not normally coded in textual form, whatever symbolic representation is conventionally used for the information should be used for encoding the prtChannelInformation value. (For instance, a binary port value might be represented as a decimal number using NVT ASCII codes.) Such encoding must be specified in the definition of the value. b. The value may contain textual information in a character set other than NVT ASCII graphics characters. (For instance, an identifier might consist of ISO 10646 text encoded using the UTF-8 encoding scheme.) Such a character set and its encoding must be specified in the definition of the value. 6. For each PrtChannelType for which prtChannelInformation entries are defined, the descriptive text associated with the PrtChannelType enumeration value shall specify the following information for each entry: Title: Brief description phrase, e.g.: 'Port name', 'Service Name', etc. Keyword: The keyword value, e.g.: 'Port' or 'Service' Syntax: The encoding of the entry value if it cannot be directly represented by NVT ASCII. Status: 'Mandatory', 'Optional', or 'Conditionally Mandatory' Multiplicity: 'Single' or 'Multiple' to indicate whether the entry may be present multiple times. Description: Description of the use of the entry, other information required to complete the definition (e.g.: ordering constraints, interactions between entries). Applications that interpret prtChannelInformation should ignore unrecognized entries, so they are not affected if new entry types are added." ::= { prtChannelEntry 9 } -- -- The Interpreter Group -- -- The interpreter sub-units are responsible for the conversion -- of a description of intended print instances into images that -- are to be marked on the media. A printer may have one or more -- interpreters. The interpreter sub-units are represented by the -- Interpreter Group in the Model. Each interpreter is generally -- implemented with software running on the System Controller -- sub-unit. The Interpreter Table has one entry per interpreter -- where the interpreters include both Page Description Language -- (PDL) Interpreters and Control Language Interpreters. -- -- Implementation of every object in this group is mandatory. prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 } -- Interpreter Table -- -- The prtInterpreterTable is a table representing the -- interpreters in the printer. An entry shall be placed in the -- interpreter table for each interpreter on the printer. prtInterpreterTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInterpreterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtInterpreter 1 } prtInterpreterEntry OBJECT-TYPE SYNTAX PrtInterpreterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtInterpreterIndex } ::= { prtInterpreterTable 1 } PrtInterpreterEntry ::= SEQUENCE { prtInterpreterIndex Integer32, prtInterpreterLangFamily PrtInterpreterLangFamilyTC, prtInterpreterLangLevel OCTET STRING, prtInterpreterLangVersion OCTET STRING, prtInterpreterDescription OCTET STRING, prtInterpreterVersion OCTET STRING, prtInterpreterDefaultOrientation PrtPrintOrientationTC, prtInterpreterFeedAddressability Integer32, prtInterpreterXFeedAddressability Integer32, prtInterpreterDefaultCharSetIn CodedCharSet, prtInterpreterDefaultCharSetOut CodedCharSet, prtInterpreterTwoWay PrtInterpreterTwoWayTC } prtInterpreterIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each PDL or control language for which there exists an interpreter or emulator in the printer. The value is used to identify this interpreter. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new interpreters to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtInterpreterEntry 1 } prtInterpreterLangFamily OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtInterpreterLangFamilyTC MAX-ACCESS read-only STATUS current DESCRIPTION "The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate." ::= { prtInterpreterEntry 2 } prtInterpreterLangLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of the PostScript language. Similarly it might contain '2' for an interpreter which is emulating level 2 of the HPGL language." ::= { prtInterpreterEntry 3 } prtInterpreterLangVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date code or version of the language which this interpreter is interpreting or emulating." ::= { prtInterpreterEntry 4 } prtInterpreterDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interpreters." ::= { prtInterpreterEntry 5 } prtInterpreterVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated." ::= { prtInterpreterEntry 6 } prtInterpreterDefaultOrientation OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtPrintOrientationTC MAX-ACCESS read-write STATUS current DESCRIPTION "The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream)." ::= { prtInterpreterEntry 7 } prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 8 } prtInterpreterXFeedAddressability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 9 } prtInterpreterDefaultCharSetIn OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-write STATUS current DESCRIPTION "The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. (Input octets are presented to the interpreter through a path defined in the channel group.) This value shall be (2) if there is no default." ::= { prtInterpreterEntry 10 } prtInterpreterDefaultCharSetOut OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-write STATUS current DESCRIPTION "The default character set for data coming from this interpreter through the printer's output channel (i.e. the 'backchannel'). This value shall be (2) if there is no default." ::= { prtInterpreterEntry 11 } prtInterpreterTwoWay OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtInterpreterTwoWayTC MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not this interpreter returns information back to the host." ::= { prtInterpreterEntry 12 } -- The Console Group -- -- Many printers have a console on the printer, the operator -- console, that is used to display and modify the state of the -- printer. The console can be as simple as a few indicators and -- switches or as complicated as full screen displays and -- keyboards. There can be at most one such console. -- Implementation of every object in this group is mandatory. -- The Display Buffer Table prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 } prtConsoleDisplayBufferTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtConsoleDisplayBufferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Physical display buffer for printer console display or operator panel" ::= { prtConsoleDisplayBuffer 5 } prtConsoleDisplayBufferEntry OBJECT-TYPE SYNTAX PrtConsoleDisplayBufferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one entry for each physical line on the display. Lines cannot be added or deleted. Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtConsoleDisplayBufferIndex } ::= { prtConsoleDisplayBufferTable 1 } PrtConsoleDisplayBufferEntry ::= SEQUENCE { prtConsoleDisplayBufferIndex Integer32, prtConsoleDisplayBufferText OCTET STRING } prtConsoleDisplayBufferIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each console line in the printer. The value is used to identify this console line. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new console lines to the printer). Values are normally expected to remain stable across successive printer power cycles." ::= { prtConsoleDisplayBufferEntry 1 } prtConsoleDisplayBufferText OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is present. Writing a zero length string clears the line. It is an implementation-specific matter as to whether the agent allows a line to be overwritten before it has been cleared. Printer generated strings shall be in the localization specified by prtConsoleLocalization. Management Application generated strings should be localized by the Management Application." ::= { prtConsoleDisplayBufferEntry 2 } -- The Console Light Table prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 } prtConsoleLightTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtConsoleLightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtConsoleLights 6 } prtConsoleLightEntry OBJECT-TYPE SYNTAX PrtConsoleLightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtConsoleLightIndex } ::= { prtConsoleLightTable 1 } PrtConsoleLightEntry ::= SEQUENCE { prtConsoleLightIndex Integer32, prtConsoleOnTime Integer32, prtConsoleOffTime Integer32, prtConsoleColor PrtConsoleColorTC, prtConsoleDescription OCTET STRING } prtConsoleLightIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer). Values are normally expected to remain stable across successive printer power cycles." ::= { prtConsoleLightEntry 1 } prtConsoleOnTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object, in conjunction with prtConsoleOffTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non-zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the status of the lamp is undefined." ::= { prtConsoleLightEntry 2 } prtConsoleOffTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object, in conjunction with prtConsoleOnTime, defines the current status of the light. If both prtConsoleOnTime and prtConsoleOffTime are non-zero, the lamp is blinking and the values presented define the on time and off time, respectively, in milliseconds. If prtConsoleOnTime is zero and prtConsoleOffTime is non-zero, the lamp is off. If prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the lamp is on. If both values are zero the status of the lamp is undefined." ::= { prtConsoleLightEntry 3 } prtConsoleColor OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtConsoleColorTC MAX-ACCESS read-only STATUS current DESCRIPTION "The color of this light." ::= { prtConsoleLightEntry 4 } prtConsoleDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor description or label of this light in the localization specified by prtConsoleLocalization." ::= { prtConsoleLightEntry 5 } -- The Alerts Group -- -- The prtAlertTable lists all the critical and non-critical -- alerts currently active in the printer. A critical alert is -- one that stops the printer from printing immediately and -- printing can not continue until the critical alert condition -- is eliminated. Non-critical alerts are those items that do -- not stop printing but may at some future time. -- The table contains information on the severity, component, -- detail location within the component, alert code and -- description of each critical alert that is currently active -- within the printer. See 2.2.13 for a more complete -- description of the alerts table and its management. -- -- Each parameter in the Trap PDU is a full OID which itself is -- indexed by the host resources MIB "hrDeviceIndex" object. In -- order for a management station to obtain the correct -- "hrDeviceIndex" associated with a particular Trap PDU, the -- "hrDeviceIndex" value can be extracted from the returned OID -- value in the Trap PDU when the PDU is received by the -- Management station. -- -- Implementation of every object in this group is mandatory. prtAlert OBJECT IDENTIFIER ::= { printmib 18 } prtAlertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtAlert 1 } prtAlertEntry OBJECT-TYPE SYNTAX PrtAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index with a device type of 'printer'." INDEX { hrDeviceIndex, prtAlertIndex } ::= { prtAlertTable 1 } PrtAlertEntry ::= SEQUENCE { prtAlertIndex Integer32, prtAlertSeverityLevel PrtAlertSeverityLevelTC, prtAlertTrainingLevel PrtAlertTrainingLevelTC, prtAlertGroup PrtAlertGroupTC, prtAlertGroupIndex Integer32, prtAlertLocation Integer32, prtAlertCode PrtAlertCodeTC, prtAlertDescription OCTET STRING, prtAlertTime TimeTicks } prtAlertIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer starting from zero every time the printer is reset. When the printer adds an alert to the table, that alert is assigned the next higher integer value from the last item entered into the table. If the index value reaches its maximum value, the next item entered will cause the index value to roll over and start at zero again. The first event placed in the alert table after a reset of the printer shall have an index value of 1. NOTE: The management application will read the alert table when a trap or event notification occurs or at a periodic rate and then parse the table to determine if any new entries were added by comparing the last known index value with the current highest index value. The management application will then update its copy of the alert table. When the printer discovers that an alert is no longer active, the printer shall remove the row for that alert from the table and shall reduce the number of rows in the table. The printer may add or delete any number of rows from the table at any time. The management station can detect when binary change alerts have been deleted by requesting an attribute of each alert, and noting alerts as deleted when that retrieval is not possible." ::= { prtAlertEntry 1 } prtAlertSeverityLevel OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtAlertSeverityLevelTC MAX-ACCESS read-only STATUS current DESCRIPTION "The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table." ::= { prtAlertEntry 2 } prtAlertTrainingLevel OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtAlertTrainingLevelTC MAX-ACCESS read-only STATUS current DESCRIPTION "See textual convention PrtAlertTrainingLevelTC" ::= { prtAlertEntry 3 } prtAlertGroup OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX PrtAlertGroupTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 } prtAlertGroupIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The combination of the prtAlertGroup and the prtAlertGroupIndex defines exactly which printer sub-unit caused the alert; for example, Input #3, Output #2, and Marker #1. Every object in this MIB is indexed with hrDeviceIndex and optionally, another index variable. If this other index variable is present in the table that generated the alert, it will be used as the value for this object. Otherwise, this value shall be -1." ::= { prtAlertEntry 5 } prtAlertLocation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7. The value (-2) indicates unknown" ::= { prtAlertEntry 6 } prtAlertCode OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX PrtAlertCodeTC MAX-ACCESS read-only STATUS current DESCRIPTION "See associated textual convention PrtAlertCodeTC" ::= { prtAlertEntry 7 } prtAlertDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elaborate on the enumerated alert or provide information in the case where the code is classified as 'other' or 'unknown'. The printer is required to return a description string but the string may be a null string." ::= { prtAlertEntry 8 } prtAlertTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time that this alert was generated." ::= { prtAlertEntry 9 } printerV1Alert OBJECT-IDENTITY STATUS current DESCRIPTION "The value of the enterprise-specific OID in an SNMPv1 trap sent signaling a critical event in the prtAlertTable." ::= { prtAlert 2 } printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 } printerV2Alert NOTIFICATION-TYPE OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode } STATUS current DESCRIPTION "This trap is sent whenever a critical event is added to the prtAlertTable." ::= { printerV2AlertPrefix 1 } -- Note that the SNMPv2 to SNMPv1 translation rules dictate that -- the preceding structure will result in SNMPv1 traps of the -- following form: -- -- printerAlert TRAP-TYPE -- ENTERPRISE printerV1Alert -- VARIABLES { prtAlertIndex, prtAlertSeverityLevel, -- prtAlertGroup, prtAlertGroupIndex, -- prtAlertLocation, prtAlertCode } -- DESCRIPTION -- "This trap is sent whenever a critical event is added -- to the prtAlertTable." -- ::= 1 -- -- Conformance Information prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 } -- compliance statements prtMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for agents that implement the printer MIB." MODULE -- this module MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup, prtOutputGroup, prtMarkerGroup, prtMediaPathGroup, prtChannelGroup, prtInterpreterGroup, prtConsoleGroup, prtAlertTableGroup } OBJECT prtGeneralReset SYNTAX INTEGER { notResetting(3), resetToNVRAM(5) } DESCRIPTION "It is conformant to implement just these two states in this object. Any additional states are optional." OBJECT prtGeneralCurrentLocalization MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtGeneralCurrentOperator MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtGeneralServicePerson MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtAuxiliarySheetStartupPage MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtAuxiliarySheetBannerPage MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtGeneralPrinterName MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtGeneralSerialNumber MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputDefaultIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaDimFeedDirDeclared MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMaxCapacity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputCurrentLevel MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaName MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputName MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputSecurity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaWeight MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaType MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaColor MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaFormParts MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputMediaLoadTimeout MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInputNextIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputDefaultIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputMaxCapacity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputRemainingCapacity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputName MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputSecurity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputMaxDimFeedDir MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputMaxDimXFeedDir MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputMinDimFeedDir MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputMinDimXFeedDir MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputStackingOrder MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputPageDeliveryOrientation MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputBursting MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputDecollating MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputPageCollated MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtOutputOffsetStacking MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtMarkerDefaultIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtMarkerSuppliesMaxCapacity MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtMarkerSuppliesLevel MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtMediaPathDefaultIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtChannelCurrentJobCntlLangIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtChannelDefaultPageDescLangIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtChannelState MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtChannelIfIndex MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInterpreterDefaultOrientation MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInterpreterDefaultCharSetIn MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtInterpreterDefaultCharSetOut MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtConsoleLocalization MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtConsoleDisable MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtConsoleDisplayBufferText MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtConsoleOnTime MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" OBJECT prtConsoleOffTime MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only" GROUP prtResponsiblePartyGroup DESCRIPTION "This group is unconditionally optional." GROUP prtExtendedInputGroup DESCRIPTION "This group is unconditionally optional." GROUP prtInputMediaGroup DESCRIPTION "This group is unconditionally optional." GROUP prtExtendedOutputGroup DESCRIPTION "This group is unconditionally optional." GROUP prtOutputDimensionsGroup DESCRIPTION "This group is unconditionally optional." GROUP prtOutputFeaturesGroup DESCRIPTION "This group is unconditionally optional." GROUP prtMarkerSuppliesGroup DESCRIPTION "This group is unconditionally optional." GROUP prtMarkerColorantGroup DESCRIPTION "This group is unconditionally optional." GROUP prtAuxiliarySheetGroup DESCRIPTION "This group is unconditionally optional." GROUP prtInputSwitchingGroup DESCRIPTION "This group is unconditionally optional." ::= { prtMIBConformance 1 } prtMIBGroups OBJECT IDENTIFIER ::= { prtMIBConformance 2 } prtGeneralGroup OBJECT-GROUP OBJECTS { prtGeneralConfigChanges, prtGeneralCurrentLocalization, prtGeneralReset, prtCoverDescription, prtCoverStatus, prtLocalizationLanguage, prtLocalizationCountry, prtLocalizationCharacterSet, prtStorageRefIndex, prtDeviceRefIndex, prtGeneralPrinterName, prtGeneralSerialNumber } STATUS current DESCRIPTION "The general printer group." ::= { prtMIBGroups 1 } prtResponsiblePartyGroup OBJECT-GROUP OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson } STATUS current DESCRIPTION "The responsible party group contains contact information for humans responsible for the printer." ::= { prtMIBGroups 2 } prtInputGroup OBJECT-GROUP OBJECTS { prtInputDefaultIndex, prtInputType, prtInputDimUnit, prtInputMediaDimFeedDirDeclared, prtInputMediaDimXFeedDirDeclared, prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputCapacityUnit, prtInputMaxCapacity, prtInputCurrentLevel, prtInputStatus, prtInputMediaName } STATUS current DESCRIPTION "The input group." ::= { prtMIBGroups 3 } prtExtendedInputGroup OBJECT-GROUP OBJECTS { prtInputName, prtInputVendorName, prtInputModel, prtInputVersion, prtInputSerialNumber, prtInputDescription, prtInputSecurity } STATUS current DESCRIPTION "The extended input group." ::= { prtMIBGroups 4 } prtInputMediaGroup OBJECT-GROUP OBJECTS { prtInputMediaWeight, prtInputMediaType, prtInputMediaColor, prtInputMediaFormParts } STATUS current DESCRIPTION "The input media group." ::= { prtMIBGroups 5 } prtOutputGroup OBJECT-GROUP OBJECTS { prtOutputDefaultIndex, prtOutputType, prtOutputCapacityUnit, prtOutputMaxCapacity, prtOutputRemainingCapacity, prtOutputStatus } STATUS current DESCRIPTION "The output group." ::= { prtMIBGroups 6 } prtExtendedOutputGroup OBJECT-GROUP OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel, prtOutputVersion, prtOutputSerialNumber, prtOutputDescription, prtOutputSecurity } STATUS current DESCRIPTION "The extended output group." ::= { prtMIBGroups 7 } prtOutputDimensionsGroup OBJECT-GROUP OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir, prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir, prtOutputMinDimXFeedDir } STATUS current DESCRIPTION "The output dimensions group" ::= { prtMIBGroups 8 } prtOutputFeaturesGroup OBJECT-GROUP OBJECTS { prtOutputStackingOrder, prtOutputPageDeliveryOrientation, prtOutputBursting, prtOutputDecollating, prtOutputPageCollated, prtOutputOffsetStacking } STATUS current DESCRIPTION "The output features group." ::= { prtMIBGroups 9 } prtMarkerGroup OBJECT-GROUP OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech, prtMarkerCounterUnit, prtMarkerLifeCount, prtMarkerPowerOnCount, prtMarkerProcessColorants, prtMarkerSpotColorants, prtMarkerAddressabilityUnit, prtMarkerAddressabilityFeedDir, prtMarkerAddressabilityXFeedDir, prtMarkerNorthMargin, prtMarkerSouthMargin, prtMarkerWestMargin, prtMarkerEastMargin, prtMarkerStatus } STATUS current DESCRIPTION "The marker group." ::= { prtMIBGroups 10 } prtMarkerSuppliesGroup OBJECT-GROUP OBJECTS { prtMarkerSuppliesMarkerIndex, prtMarkerSuppliesColorantIndex, prtMarkerSuppliesClass, prtMarkerSuppliesType, prtMarkerSuppliesDescription, prtMarkerSuppliesSupplyUnit, prtMarkerSuppliesMaxCapacity, prtMarkerSuppliesLevel } STATUS current DESCRIPTION "The marker supplies group." ::= { prtMIBGroups 11 } prtMarkerColorantGroup OBJECT-GROUP OBJECTS { prtMarkerColorantMarkerIndex, prtMarkerColorantRole, prtMarkerColorantValue, prtMarkerColorantTonality } STATUS current DESCRIPTION "The marker colorant group." ::= { prtMIBGroups 12 } prtMediaPathGroup OBJECT-GROUP OBJECTS { prtMediaPathDefaultIndex, prtMediaPathMaxSpeedPrintUnit, prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed, prtMediaPathMaxMediaFeedDir, prtMediaPathMaxMediaXFeedDir, prtMediaPathMinMediaFeedDir, prtMediaPathMinMediaXFeedDir, prtMediaPathType, prtMediaPathDescription, prtMediaPathStatus} STATUS current DESCRIPTION "The media path group." ::= { prtMIBGroups 13 } prtChannelGroup OBJECT-GROUP OBJECTS { prtChannelType, prtChannelProtocolVersion, prtChannelCurrentJobCntlLangIndex, prtChannelDefaultPageDescLangIndex, prtChannelState, prtChannelIfIndex, prtChannelStatus, prtChannelInformation } STATUS current DESCRIPTION "The channel group." ::= { prtMIBGroups 14 } prtInterpreterGroup OBJECT-GROUP OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel, prtInterpreterLangVersion, prtInterpreterDescription, prtInterpreterVersion, prtInterpreterDefaultOrientation, prtInterpreterFeedAddressability, prtInterpreterXFeedAddressability, prtInterpreterDefaultCharSetIn, prtInterpreterDefaultCharSetOut, prtInterpreterTwoWay } STATUS current DESCRIPTION "The interpreter group." ::= { prtMIBGroups 15 } prtConsoleGroup OBJECT-GROUP OBJECTS { prtConsoleLocalization, prtConsoleNumberOfDisplayLines, prtConsoleNumberOfDisplayChars, prtConsoleDisable, prtConsoleDisplayBufferText, prtConsoleOnTime, prtConsoleOffTime, prtConsoleColor, prtConsoleDescription } STATUS current DESCRIPTION "The console group." ::= { prtMIBGroups 16 } prtAlertTableGroup OBJECT-GROUP OBJECTS { prtAlertCriticalEvents, prtAlertAllEvents, prtAlertSeverityLevel, prtAlertTrainingLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode, prtAlertDescription, prtAlertTime } STATUS current DESCRIPTION "The alert table group." ::= { prtMIBGroups 17 } -- -- prtAlertTimeGroup has been DEPRECATED (prtMIBGroups 18 ) -- prtAuxiliarySheetGroup OBJECT-GROUP OBJECTS { prtAuxiliarySheetStartupPage, prtAuxiliarySheetBannerPage } STATUS current DESCRIPTION "The auxiliary sheet group." ::= { prtMIBGroups 19 } prtInputSwitchingGroup OBJECT-GROUP OBJECTS { prtInputMediaLoadTimeout, prtInputNextIndex } STATUS current DESCRIPTION "The input switching group." ::= { prtMIBGroups 20 } END Update the MIB references to SMIv2, and the conformance statements.